Atomic Absorption Spectrophotometer - WFX-110A/120A/130A

Atomic Absorption Spectrophotometer, 1.oxygen air-acetylene flame, 2.graphite furnace analysis, 3.flame analysis, 4.PC control - more info check here: http://www.buymeasuringtools.com/Atomic-Absorption-Spectrophotometer-10267890/

Quick Brief

Place of Origin: Beijing China (Mainland) Brand Name: RAYLEIGH Model Number: WFX-110A/120A/130A

Product Features:

Atomic Absorption Spectrophotometer

1.oxygen air-acetylene flame

2.graphite furnace analysis

3.flame analysis

4.PC control

Business Terms:

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 30 Set/Sets per Month

Payment Terms: L/C,T/T

Contact Supplier
Atomic Absorption Spectrophotometer
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Wooden Cases

Delivery Detail: One Month

Specifications and Product Details:

FEATURES:

1 Innovated rich oxygen air-acetylene flame analysis technique(WFX-110A):

The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temeperature is continuously adjustable between 2300-2950°C, with makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame will not pollute the environment and is not harmful to human bodies. It's break-through in flame AAS analysis

2 Integrated flame/graphite furnace atomization system, changeable with flame emission burner

2.1 Automatically controlled changeover of the integrated flame and graphite furnace atomizer featuring easy operation and time saving eliminates human labor.

2.2 A flame emission burner head can be installed to perform flame emission analysis to Alkali metals as K, Na etc.(WFX-110A/120A)

3 Accurate fully automated control system

3.1 Automatic multi-lamp turret, automatic adjustment of lamp current and optimization of light beam position

3.2 Automatic wavelength scanning and peak picking

3.3 Automatic spectral bandwidth changing

3.4 Automatic changeover between flame and graphite furnace operation, automatic optimization of position parameters and automatic ignition

4 Reliable fully automatic graphite furnace analysis

4.1 Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity. The temperature control accuracy is less than 1%

4.2 Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact

5 Perfect safety protection measures

5.1 Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system

5.2 Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling wate supply and over-heating in graphite furnace system

6 Advance and reliable electronic design

6.1 Adopting large-scale programmable logic array and Inter I2C bus technology

6.2 European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system

7 Easy and practical analysis software

7.1 Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and

optimization

7.2 Automatic display of measured data, automatic calculation and analytical result automatic print out.

SPECIFICATIONS:

Main Specification

Wavelength range190-900nm
Wavelength accuracyBetter than ±0.25nm
ResolutionTwo spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.
Baseline stability0.004A/30min
Background correction
The D2 lamp background correction capability at 1A is better than 30 times
The S-H background correction capability at 1.8A is better than 30 times.( only for WFX-110A/120A)
Hollow Cathode LampsLamp turret6-lamp turret (WFX-110A/120A), 4-lamp turret (WFX-130A); Auto-alignment, fully automated scan and peak-picking.
Lamp current adjustment400Hz square wave pulse

Wide pulse current: 0~25mA,
Narrow pulse current: 0~10mA

Lamp power supply mode400Hz square wave pulse;

100Hz narrow square wave pulse+400Hz wide square wave pulse (WFX-110A/120A)

Optical SystemMonochomatorSingle beam, Czerny-Turner design grating monochromator
Grating1800 l/mm
Focal length277mm
Blazed Wavelength250nm
Spectral Bandwidth0.1nm, 0.2nm, 0.4nm, 1.2nm, automatic change
Flame AtomizerBurner10cm single slot all-titanium burner
Spray chamberCorrosion resistant all-plastic spray chamber
NebulizerHigh efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min
Emission burner provided with WFX-110A/120A
Graphite FurnaceTemperature rangeRoom temperature~3000ºC
Heating rate2000°C/s
Graphite tube dimensions28mm(L)×8mm(OD)
Characteristic massCd≤0.5 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g
PrecisionCd≤3%, Cu≤3%, Mo≤4%
Detection and Data Processing SystemDetectorR928 Photomultiplier with high sensitivity and wide spectral range.
SoftwareWindows operating system
Analytical methodWorking curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content.
Repeat timesMaximum 20 times of repeat measurement, automatic calculation of mean value, standdard deviation and relative standard deviation.
Multi-task FunctionsSequential measurement for multi-element determination in one sample
Condition readingWith model function
Result printingMeasurement data and final analytical report printout, editing with Excel
Standard RS-232 serial port communication
Characteristic Concentration and Detection Limit

Normal Air-C2H2 flame

Oxygen-rich Air-C2H2 flame

Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;
Ba: Characteristic concentration ≤ 0.22mg/L
Al: Characteristic concentration ≤ 0.4mg/L
Function Expansion
Hydride vapor generator can be connected for hydride analysis
Dimensions and weightMain unit102×49×54cm, unpacked 80kg
Graphite furnace42×42×46cm, unpacked 50kg