Home  >  Optical Instruments  >  Spectrometers

Atomic Absorption Spectrophotometer - WFX-110B

WFX-110B Atomic Absorption Spectrophotometer, 1.Wavelength range 190-900nm, 2.Wavelength accuracy -0.25nm ~ +0.25mm - more info check here: http://www.buymeasuringtools.com/Atomic-Absorption-Spectrophotometer-10189197/

Quick Brief

Place of Origin: Shandong China (Mainland) Brand Name: UNICOM-OPTICS or Neutral English Model Number: WFX-110B Wavelength Range: 190-900nm Power Supply: 220V, 200W

Product Features:

WFX-110B Atomic Absorption Spectrophotometer

1.Wavelength range 190-900nm

2.Wavelength accuracy -0.25nm ~ +0.25mm

Business Terms:

Port: Qingdao port

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 6,000.00 Set/Sets per Year

Payment Terms: T/T

Contact Supplier
Atomic Absorption Spectrophotometer
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Carton

Delivery Detail: 14 Days

Specifications and Product Details:

WFX-110B Atomic Absorption Spectrophotometer

The patented flame analysis technique adopting oxygen-rich air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses.
Automatic hollow cathode lamp changeover. The high performance HCL can be used directly.
Auto-changeover and position optimization of integrated flame.
Auto-ignition, automatic spectral bandwidth selection. Fully automated wavelength scanning and peaking


Perfect safety protection measures, alarm and automatic safety protection to fuel gas leakage, air pressure deficiency and abnormal flame extinction; spray chamber made of explosion-proof material, all-titanium burner and explosion-proof stopper for flame analyses; alarm and protection function to argon pressure deficiency, insufficient cooling water supply, over-heating and over-current etc. in graphite furnace analyses.


Adopting large-scale programmable logic array and Inter IC bus technique and highly reliable adapters for electric design.


Easy and flexible WINDOWS operating system, with multi-windows processing technology to observe the signal profile, the measured results and the calibration curve at the same time. Various analytical programs, data, signals and graphics can all be stored for later use.

Main Specification

Wavelength range190-900nm
Wavelength accuracy±0.25nm
ResolutionTwo spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.
Baseline stability≤0.004A/30min
Background correctionThe D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times.

Hollow Cathode Lamps

Lamp turret6-lamp turret, fully automated scan and peak-picking.
Lamp current adjustmentAutomatic adjustment and display. Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA
Lamp power supply modePowered by two pulses simultaneously

Optical System

MonochomatorSingle beam, Czerny-Turner design grating monochromator
Grating1800 l/mm
Focal length277mm
Blazed Wavelength250nm
Spectral Bandwidth0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change.
AtomizerFlame/GraphiteFlame & Graphite Furnace atomizer automatic changeover

Detection and Data Processing System

DetectorPhotomultiplier with high sensitivity and wide spectral range.
SoftwareMs-Windows 98/Me operating system
Analytical methodWorking Curve Method (1st order and 2nd order fitting), Sensitivity auto-correction, Standard Addition Method.
ConcentrationAuto-calculation of concentration and content
Repeatable measurementMaximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation.
Multi-task functionSequential measurement of multi-elements in one sample
Condition readingWith model function
Result printingMeasurement data and final analytical report printout, editing with Excel.

Flame Analysis

Burner10cm single slot all-titanium burner
Spray chamberAll-plastic spray chamber.
NebulizerHigh efficiency glass nebulizer with metal sleeve.
Position adjustmentAdjusting mechanism for vertical, horizontal positions and the rotation angle of the burner.
Protection for gas systemFuel gas leak protection, abnormal flame extinction alarm, air-pressure deficiency protection and explosion-proof device.
Flame ignitionAutomatic

Characteristic Concentration and Detection Limit

Normal Air-C2H2 flameCu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;
Oxygen-rich Air-C2H2 flameBa: Characteristic concentration ≤ 0.22mg/L Al: Characteristic concentration ≤ 0.4mg/L
Hydride generationHg: detection limit≤0.5ug/L
Power Supply

220V, 200W

Dimensions

1020 (L) × 492 (W) × 537 (H) mm (main unit)

420 (L) × 420 (W) × 460 (H) mm (graphite furnace)

Weight

Unpacked 80kg (main unit), 50kg (graphite furnace)

Atomic Absorption Spectrophotometer suppliers    Atomic Absorption Spectrophotometer manufacturers