Atomic Absorption Spectrometer AE-AA990
Port: Beijing,Shanghai,Guangzhou
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 100 Set/Sets per Week
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: Standard export packing
Delivery Detail: within 7~10 days after having received the payment
Features:
Fully Automated
1.The flame and graphite furnace is integrated into one instrument.The change over from one technique to another is carried out by simple key strokes within the software.
2.The instruments have a motorised 8 hollow cathode lamp turret which allows the automatic positioning and optimisation of each hollow cathode lamp by the software.
3. The control of the gas flows for the fuel gas (C2H2 ) and the positioning of the bumer is also carried out directly from the software thus allowing optimization of the instruments for the best analytical parameter for a selected analysis.
4. Two methods of background correction are available.The first utilises a deuterium lamp and the second is the proven method of self reversal.
5. The location of the wavelength and peak selection is automatic and controlled from the software. The spectral bandwidth is automated and is available with a choice of five slit sizes.
6. The electronic parameters for the photomultiplier detector,the hollow cathode lamp current and the balancing of the absorbance and background energies are controlled from the software.
7.The igntion of the flame is computer controlled and the various safety interlocks offer a very safe operating system.
Technical Specifications
Model | AE-AA990 |
Optic System | |
Wavelength Range | 190nm-900nm |
Monochromator | Czemy-Turner Configuration |
Spectral Bandwidth | 0.1nm,0.2nm,0.4nm,1.0nm,2.0nm(5steps. with automatic change over) |
Wavelength Accuracy | ±0.25nm |
Wavelength Repeatability | 0.15nm |
Baseline Stability | 0.005A/30min |
Flame analysis
Sensitivity(Cu): 0.03μg/ml/1%
Burner Head: Titanium alloy burner
Atomization Chamber: Corrosion-resistant material
Position Adjustment: Automatic Changeover of Flame and Furnace
Automatic setting of Optimum Height for Flame Burner
Safety: Automatic ignition and mixing air-acetylene gas with safety control.
Graphite furnace analysis
Character Value(Cd): 0.5Pg
Temperature Range: Ambient-2650°C
Heating: Voltage feedback control when dry and ashing;
Optical temperature control when atomizing.
Heating program: Up to 9 steps with choices of ramp,temperature increase
and full-power heating