Specifications and Product Details:

Anticorrosive Submersible Liquid Level Transmitters Model LV35

Based on silicon piezoresistive technology, model LV35 submersible Liquid level transmitter is designed for use in applications where the pressure is created by corrosive pressure media. The pressure diaphragm is made from tantalum and the housing is made from PVDF. LV35 level transmitters are designed for gauge pressure measurements.


Lv35 level transmitters are made of a Wheatstone bridge circuit. Various output signals, including millivolts signal (80 mV@1 mA) and amplified signals (4~20 mA, 0~5 V or 0~10 V), are available. The measuring accuracy is up to 0.25 %fso. These transmitters possess low temperature coefficients of 0.02 %fso/oC for both Zero and Span within the compensated temperature range (0~50 oC).

Features:

1. for alkali corrosive medium
2. wide measuring ranges: 0~1, ..., 0~10 mH2o
3. various output signals: transducers: full scale output 80 mV@1mA
transmitters: 4~20 mA, 0~5V or 0~10 V
4. measuring accuracy: 0.25 %fso (standard), 0.5 %fso
5. materials: tantalum (pressure membrane); PVDF (housing)
6. housing environment protection: IP 68

Specification:

measuring media

liquids which are compatible with PVDF

measuring ranges

mH2O0~1,0~2,0~3,0~5,0~10

overload pressure

%FS150

output signal

transducersmV80 (full scale output @ 1mA)
transmittersmA or Vdc4~20 mA or 0~10 V

power supply

transducersmA1 (recommended, 0.5, 2
transmittersVdc24 (recommended, 18,, 36

accuracy

%FSO± 0.25(standard), ± 0.5

long-term stability

%FSO/year< ± 0.5

response time

ms<1 (10%~90% of leading edge)
input resistancetransducersΩ2000~8000
output resistancetransducersΩ3500~6000
Load resistancetransmittersΩ250~1150

insulation resistance

>500 @ 100 Vdc (transducer only

storage temperature range

-40~+100

operating temperature range

0~+80

compensated temperature ranges

0~+50

temperature coefficient of ZERO

%FSO/±0.02

temperature coefficient of SPAN

%FSO/±0.02

process connection

submersible in liquid

electrical connection

4-core,7.6 mm shielded cable with vent hose which is mechanically strong enough for deep submersible liquid level measurements

pressure membrane material

tantalum

housing material

PVDF

environment protection

IP ratingIP 68

weight

gram200probe head+the weight of cable

How to order: model - range - output - accuracy - cable length - customer specific requests

ordering code example: LV35 - 0~5 mH2O - 4/20 mA - 0.25%fso - 5 m

Anticorrosive Submersible Liquid Level Transmitters Model LV35 suppliers    Anticorrosive Submersible Liquid Level Transmitters Model LV35 manufacturers