Home  >  Temperature Instruments

Air Velocity Transmitters 0-10m/s - ASP-U

air velocity transmitters/sensor, testing wind speed of HVAC, output: 0-10V or 4-20mA, AC24/DC24, 0-2m/s 0-10m/s 0-20m/s - more info check here: http://www.buymeasuringtools.com/Air-Velocity-Transmitters-0-10m-s-10120820/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: CH-BA Model Number: ASP-U Usage: Outdoor Theory: air velocity

Product Features:

air velocity transmitters/sensor

testing wind speed of HVAC

output: 0-10V or 4-20mA

AC24/DC24

0-2m/s 0-10m/s 0-20m/s

Business Terms:

Port: Shanghai

Minimum Order Quantity: 50 Piece/Pieces

Supply Ability: 500 Piece/Pieces per Month

Payment Terms: L/C,T/T,Western Union

Contact Supplier
Air Velocity Transmitters 0-10m/s
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

Measuring Theory

ASP-U-D air velocity transmitter is a ideal opotion for accurate vetilation control. The innovation of the working theory is using the pitot tube(The pitot tube is for testing the pressure).Becuase of the simple stucture, the convenient use, and the perfect theoretical study, this methord is widely used. Pitot tube test according the pressure which caused by liquit flow. The standard pitot tube is composed by inner tube, outer tube and the HIP catheter. It can detect the higher pressure, medium pressure and the low pressure which insure the accuracy and the average the the test. On the top of pitot tube, there is a small hole which is vertically with the direction of the fluid flow. The hole on the top and the side is connect with the two pips of each others. The air pressure which enter into the top the the pitot tube is called overall pressure. Escept the HIP pressure of the flow, it also contains the pressure translated by the kinetic energy which caused by the fluid stagnation. The pressure enter the hole of the side is only the HIP pressur. According the overrall pressure and the HIP pressure we can caculate the dymatic pressure. Then caculate the velocity.

Technical Data

ModleASP-U
Mesuring Range0-15m/s
Accuracy of Measurement0.20%
Accuracy0.05m/s
Power supplyAC15...26V DC13...24V
Frequency50/60HZ
Output010V
Power10W

Allowable cable lenth

0.5mm2BVVR cable 70m
1.0mm2BVVR cable 200m
1.5mm2BVVR cable 350m
Other non-shielded cables use shorter cable
Connection Terminal BlockScrew Connect Terminal Block 3X1.5mm2

Working Enviroment

Temperature: -5+70
Humidity:5%-95%
LenthStandard:350mm (can be ordered according the requirement)
Color:Off white\gray
Air Velocity Transmitters 0-10m/s suppliers    Air Velocity Transmitters 0-10m/s manufacturers