Acid flow meter - AM200/300

AM200/300 acid flow meter, 1>High Accurcacy, 2>Multi Output:pulse,4-20mADC,RS485,RS232 e.g. - more info check here: http://www.buymeasuringtools.com/Acid-flow-meter-10048051/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: HUGE Model Number: AM200/300 Accuracy: 0.5% of flowrate AC power supply common use: 80-264VAC With multiform communication e.g: RS485 RS232 C... The velocity range: 0.3m/s to 15m/s

Product Features:

AM200/300 acid flow meter

1>High Accurcacy

2>Multi Output:pulse,4-20mADC,RS485,RS232 e.g.

Business Terms:

Port: Shanghai

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 500 Set/Sets per Month

Payment Terms: T/T

Contact Supplier
Acid flow meter
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: 1

Delivery Detail: five working days

Specifications and Product Details:

AM200/300 acid flow meter is the advanced engineering designed magnetic flowmeter, It has a dual cavity housing providing ease of wiring while isolating the electronics from the environment. AM200/300 continues the use of low frequency excitation, which provides noise free output. AM200/300 excitation method and multiform lining allow this magnetic flowmeter to be applied to an even greater range of applications

FEATURES

  • Fast response and high stability.
  • High Accuracy, 0.5% of flowrate.
  • Dual cavity housing to separate electronics part from wiring part.
  • AC power supply common use (80/264V).
  • High visible backlit LCD for easy operation.
  • With multiform communication e.g. RS485,RS232C,HART,Pfofibus,MODBUS etc.
  • Bi-direction measuring and totalizing


  • STANDARD SPECIFICATIONS

    I;Converter
    Measuring Range
    The velocity range is 0.3m/s to 15m/s. The minimum measurable speed can be one percent (1%) of the full range.

    Accuracy

    DN
    (mm)
    Velocity
    m/s
    Accuracy
    25
    ~
    1200
    0.1~0.3±0.25%FS
    0.3~1±0.5%R
    1~15±0.3%R
    %FS:Relative range;%R:Relative measured


    Analog Output
    Current output: fully-isolated 0 - 10mA / 4 - 20mA
    Load resistance: 0 to 1.5kΩ at 0 - 10mA; 0 to 750Ω at 4 - 20mA
    Base error: add ±10μA on top of the measurement error

    Frequency Output
    Frequency output is proportional to the flow percentage of the full range. It provides fully isolated transistor open collector frequency output ranged from 1 to 5000 Hz. The external DC power supply should not exceed 35V and maximum collector current is 250mA.

    Pulse Output
    The converter can output up to 5000cp/s pulse series, which is dedicated to external totalization. Pulse factor is defined as pulse count per unit volume or mass. It can be set to 0001-9999p/L, 0001-9999p/m3, 0001~9999p/kg or 0001~9999p/t. Pulse width is selectable from 16ms, 33 ms, 66mm, 99ms or auto square wave. Photo-coupler isolated transistor open collector circuit is used for pulse output. The external DC power supply should not exceed 35V and maximum collector current is 250mA.

    Showing Flow Direction & Range
    The converter is capable of measuring both forward and reverse flow and recognizing its direction. The converter outputs 0V low level for forward flow, while +12V high level for reverse flow.

    Alarm Out
    Two channels of photo-coupler isolated open collector circuit are used for alarm signal output. There are two alarm outputs: high limit alarm and low limit alarm. The external DC power supply should not exceed 35V and maximum collector current is 250mA.

    Communication
    The RS485, RS232C, HART, Profibus, MODBUS communication interface are embedded in the converter. Surge absorber is optional to protect the interface and converter.

    Damping Constant
    Damping time is optional from 0.2 to 100s

    Input Contact
    External contact ON (close) or OFF (open) signal can be used to remotely control the start/stop or reset of internal counter.

    Display Function
    Flow rate can be displayed either in engineering units or in percent of span. Totalized volume in any engineering unit can be displayed by setting a totalizing factor.

    Self Diagnostics Function
    Converter failure, flow tube failure, erroneous setting, etc. can be diagnosed and displayed.

    Data Security During Power Failure
    Data storage by EEPROM - no back-up battery required

    Electrical Connection
    ISO M20´1.5 female

    Terminal Connection
    M4 size screw terminal

    Case Material
    Aluminum alloy

    Coating
    Polyurethane corrosion-resistant coating. Cover; Deep sea moss green (Munsell 0.6GY3.1/2.0) Case; Frosty white (Munsell 2.5Y8.4/1.2)

    Protection
    IP67, NEMA4X

    II;Magnetic Flow Tube
    Nominal Diameter

    LiningRubberPTFEPFA
    DN
    (mm)
    25,32,40,50,65,80,100
    125,150,200
    250,300,350
    400,450,500,600,700,800,900
    1000,1200
    25,32,40,50
    65,80,100
    125,150,200
    250,300,350
    400
    25,32,40
    50
    65,80,100



    Flow Tube Material
    Size 25 to 100 mm

  • Housing: Stainless steel (SUS304)
  • Flange: Stainless steel (SUS304)
  • Pipe: Stainless steel (SUS304)

  • Size 150 to 1200 mm

  • Housing: Carbon steel (SPCC)
  • Flange: Carbon steel (SS400)
  • Pipe: Stainless steel (SUS304)


  • Wetted Part Material

  • Lining: Rubber, PTFE or PFA
  • Electrode: Stainless steel (SUS316L), Hastelloy C,Titanium,Tantalum, Platinum
  • Earth Ring/Earth Electrode: Stainless steel (SUS316)


  • NORMAL OPERATING CONDITIONS

  • Ambient Temperature: -20 to 60°C
  • Ambient Humidity: 5 to 95%RH
  • Power Supply Voltage: 80 to 264 V AC
  • Fluid Conductivity:20mS/cm or larger


  • MODEL AND SUFFIX CODE



    Dedicated Signal Cable

    ModelSuffix CodeDescription
    AM011………………….flowmeter
    End treatment-0……………..
    -1………………
    Non termination
    Terminated
    Cable length-L……….Enter the length in m (Max 30m)
    Acid flow meter suppliers    Acid flow meter manufacturers