AVS100 Series Vortex Flow Meter is widely used to measure the flow rate of steam, gas and liquid, e.g. saturated steam, superhea
Port: SHANGHAI
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 500000 Unit/Units per Year
Payment Terms: L/C,T/T,Western Union
Contact SupplierPackaging Detail: Wood packing
Delivery Detail: Within 3 days
AVS100 Series Vortex Flow Meter
Application:
AVS100 Series Vortex Flow Meter is widely used to measure the flow rate of steam, gas and liquid, e.g. saturated steam, superheated steam, compressed air.
Features:
-Medium: Superheated Steam, Saturated Steam, Compressed Air, water, other gases and liquids.
-Accuracy: +/-1.0% (liquid), +/-1.5% (gas)
-Rated Pressure (optional): 1.6MPa, 2.5MPa, 4.0MPa
-Temperature of Medium: -40°C~+350°C
-Operated Power: 24V DC, Built in battery (can work lasting for 2 years)
-Output Signal (optional): 4-20mA, RS-485, HART
-Protection Grade: IP65
-Ambient Temperature: -40°C~+60°C (without LCD), 0°C~+60°C (with LCD)
-Ex-proof: Exd II BT3-6
Model Selection:
Code | Description | |
Factory Marks | AVS100 | Vortex Flow Meter Produced By SHANGHAI ANJUN |
Option | /EX | Ex-Proof |
Normal Diameter | -XXX | -006:DN6, -010:DN10, 02:DN25, 03:DN32, 04:DN40, 05:DN50, 06:DN65, 08:DN80, 10:DN100, 12:DN125, 15:DN150, 20:DN200, 25:DN250, 30:DN300 |
Material of Body | -C, F, M | C-CS, F-SS304, M-SS361L |
Medium | L, G, S | L-Liquid, G-Gas, S-Steam |
Rated Temperature | 1, 2, 3 | 1-(-40~+45°C), 2-(≤250°C), 3-(≤350°C) |
Rated Pressure | 1, 2, 3 | 1-(≤1.6MPa), 2-(≤2.5MPa), 3-(≤4.0MPa) |
Output | P | Pulse Signal (without display) |
I | Local Display (Battery Powered) | |
E | Local Display with 4-20m A (24VDC) | |
U | Local Display with 24V powered | |
F | Two Wires (4-20m A, 24VDC, without display) | |
D | Intelligence Type | |
Installation | J, H, C, R | J-Clamp on with Flange, H-Connection with Flange, C-Insertion, R-Threaded |
Example: AVS100-015-FL11PJ
Description: AVS100-Factory Mark, 015-DN15, F-SS304 Body, L-Liquid, 1-Normal Temperature, 1-Rated Pressure≤1.6MPa, P-Pulse Signal, J-Clamp on with Flange, Without Ex-proof Function.