AT-F1000C Frequency Counter - AT-F1000C

AT-F1000C Frequency Counter,10 Hz ~ 1000MHz,8-Digit LED display,Few switches, Well operability,Zero reset - more info check here: http://www.buymeasuringtools.com/AT-F1000C-Frequency-Counter-10196109/

Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: ATTEN Model Number: AT-F1000C Display Type: Digital Only Measuring Range: 10 Hz ~ 1000MHz Voltage: 220VAC ± 10% 50Hz Operating Temperature: -5C ~ + 50C

Product Features:

AT-F1000C Frequency Counter,10 Hz ~ 1000MHz,8-Digit LED display,Few switches, Well operability,Zero reset

Business Terms:

Port: Shenzhen

Minimum Order Quantity: 10 Set/Sets The more,the cheaper!

Supply Ability: 10500 Set/Sets per Week

Payment Terms: T/T,Western Union,MoneyGram

Contact Supplier
AT-F1000C Frequency Counter
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

AT-F1000C Frequency Counter

PRODUCT DESCRIPTION

AT-F Series Frequency Counter is 8-bit high-brightness LED display advanced frequency counter with, 4 function operation, low power circuit design, small size, and light weight. It have a high-stability crystal oscillator temperature protection (TCXO high temperature stability of security compensation oscillator 13MHz) to ensure measurement accuracy and wide to check the input signal with frequency, period and cumulative.

It has the self-test features such as the choice of input signal attenuation function. The feature and functions are controlled by a large-scale microprocessor.

FEATURES

8-Digit LED display
Few switches, Well operability
Quickness, High resolution
Compact Design, Excellent for field operations
Self-locking manual lock
Zero reset

TECHNICAL SPECIFICATIONS

Frequency range10 Hz ~ 1000MHz
Frequency display8-bit high-brightness LED
Gate Time0.01S/0.1S/1S
Accuracy± 1HZ ± 1 count figure ± Time base accuracy
Time-base frequency13 MHz
Short-term stability± 3 × 10-9 / S
Long-term stability± 1 × 10-5,0C ~ 40C
Line voltage change± 10% each
the time-base frequency± 1 × 10-7
Measurement accuracy± time base error ± trigger error × was
OscillatorTCXO (temperature of the high stability oscillator compensation 13MHz)

Channel 1 (CH1)

Input Sensitivity10MHz file (10Hz ~ 8MHz) : 75Vrms
10MHz file (8MHz ~ 10MHz) : 30Vrms
100MHz file (10MHz ~ 80MHz): 30Vrms
100MHz file (80MHz ~ 100MHz) : 30Vrms
Attenuator× 1, 1 / 20
Impedanceapproximately 1MΩ (less than 35pF)
Maximum security voltage250V (DC + ACrms, ATT buy 1 / 20)

Channel 2 (CH2)

Input Sensitivity1GHz file (100MHz ~ 1000MHz): 30Vrms
Impedance50Ω
Maximum security voltage3V
Input power220VAC ± 10% 50Hz
Power consumptionabout 10W
Working environment-5C ~ + 50C
Size230 × 210 × 76 (W × H × D) mm
Weight1.8Kg