Home  >  Testing Equipment

AC Resonance Withstand Voltage Test system

resonance test system, 1.Composed by power control cabinet, 2.excitation transformer, reactor, voltage divider. - more info check here: http://www.buymeasuringtools.com/AC-Resonance-Withstand-Voltage-Test-system-10106763/

Quick Brief

Place of Origin: Hubei China (Mainland) Brand Name: Huatian Power: Electronic Usage: Auto Testing Machine Rated output voltage: 0~1000kV Output frequency: 30~300Hz Quality factor: 30~90

Product Features:

resonance test system

1.Composed by power control cabinet

2.excitation transformer, reactor, voltage divider.

Business Terms:

Port: wuhan/shanghai

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 5 Set/Sets per Day

Payment Terms: L/C,T/T,Western Union

Contact Supplier
AC Resonance Withstand Voltage Test system
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: carton or wooden case

Delivery Detail: 20 days after everything be confirmed

Specifications and Product Details:

resonance test system,AC Resonance Withstand Voltage Test system,high voltage test system

Transformer, GIS, SF6 switch, CT/PT, insulator, bus bar, cable, bushing, and others capacitive devices are the common primary electric equipments. Composed by power control cabinet, excitation transformer, reactor, voltage divider, connect silicon rectifier stack and micro ammeter with the voltage divider, then can finish the DC voltage withstand test.

Products features

1.It with smaller volume, lighter weight compared with others reactors which in same voltage class and capacity. With small temperature rise under rated load; strong mechanical strength, good insulation performance, reliable.
2.The capacity of the power control cabinet is high; strong protection function; good output waveform; good stability; multi function, easy to operate; single phase 220V or three phase 380V are available.
3.Can match different kinds reactors, multifunctional, highly cost effective

Product parameters

Rated output voltage0~1000kV
Output frequency30~300Hz
Voltage waveformSine wave,distoration≤1.0%
Working formFull power continuous working time 60min
Quality factor30~90
Frequency adjustment sensitivity0.1Hz
Instability<0.05%

Power supply

Single phase 220V or three phase380V±10%
Frequency: 50Hz±5%

Serial product and application:

Model

Application(10kV~500kV transformer substation AC voltage withstand equipment, frequency: 30~300Hz )

Frequency power sourceResonant reactorExcitation transformerDividerApplication
BPXZ-50/50/253kW25kV/1A:2 sets
( dry type )
3kVA
( dry type )
50kV10kV transformer ≤1000kVA
10kVswitch, bus bar, PT,CT, etc.
10kV(300mm2)cable≤1.0km
BPXZ-108/108/275kW27kV/1A:4 sets
( dry type )
5kVA
( dry type )
110kV35kV transformer ≤31500kVA

35kV switch, bus bar, PT,CT, etc.
10kV(300mm2)cable: 2km
35kV (300mm2)cable: 0.5km

BPXZ-200/200/5010kW50kV/1A:4 sets
( dry type )
10kVA
( dry type )
200kV110kVtransformer≤ 50000kVA
110kVGIS,PT,CT, etc.(preventive trial)
35kV(300mm2)cable≤1.0km
10kV (300mm2)cable≤2.0km
BPXZ-270/270/4515kW45kV/1A:6 sets
( dry type )
15kVA
( dry type )
300kV110kVtransformer≤ 50000kVA
110kVGIS,PT,CT, etc.
35kV(300mm2)cable≤1.2km
10kV (300mm2)cable≤3.0km
BPXZ-800/400/5030kW50kV/2A:8 sets
( dry type )
100kV/2A:4 sets
(oil immersed)
30kVA
( dry type )
30kA

(oil immersed)

400kV220kV transformer ≤80000kVA

110kVtransformer≤ 50000kVA
110kV/220kVGIS,PT,CT, etc.
35kV(300mm2)cable≤2.0km
110kV (300mm2)cable≤0.7km

BPXZ-1600/800/20060kW200kV/2A:4 sets
(oil immersed)
60kVA
( dry type )
800kV220kV transformer ≤80000kVA

110kVtransformer≤ 50000kVA
500kVGIS,PT,CT, etc.
220kVswitch,GIS,PT,CT, etc.
110kV(400mm2) cable≤1.5km
220kV (400mm2) cable≤1.0km

Note: can make the solution according the parameters of the measured equipment.