Pachymeter&A scan
Port: Shanghai
Minimum Order Quantity: 1 Piece/Pieces
Payment Terms: L/C,T/T,Western Union
Contact Supplier
Specification | 1.Working conditions | Environmental temperature:5°C-40°C,Relative humidity not more than 80%. | Power supply:AC 100V-240V,50/60 Hz. | 2.Corneal Thickness Pachymeter | Ultrasonic frequency:15~20MHz | Display resolution:1μm | Measuring scope:0.23mm-1.2mm | Biometry accuracy:≤± 5μm | 3.Safety: | Satisfy the requirements of IEC 60601-1 and IEC 60601-2-37 | Features: | 1.Precise Measurement with both Immersion&Contact | 2.Extremely Easy Use | 3.Portable & Sleek Design | 4.Auto/Manual Modes | 5.Auto Gain Control | 6.Built-in thermal printer | 7.Clinical Accuracy: ±0.1mm | 8.Data with Graph Printout | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pachymeter | Probe 20MHz, angle of 45 degrees makes easier operation. | precision 5μm | Measure range 300μm~1500μm | each group is the average of 10 measures. | Output LCD display and thermal print | Display Large color liquid-crystal screen | SINGLE mode and MAP mode | A scan | Probe 10MHz, with LED | Depth 15mm-35 mm | Precision ±0.05mm | Examining Method immersion and contact | Eye Mode Phakic/ Aphakic/Pseudo | IOL Formula SRK-II, SRK-T, HOFFER-Q, HOLLADAY,BINKHORST-II, HAIGIS | Curve Freeze control by foot switch auto freeze and manual freeze. | Output A scan table,thermal printer and calculation | Store 10 cases(eyes), 5 reading each case | Display Large LCD | Manual and auto modes |
Specification | |||
1.Working conditions | |||
Environmental temperature:5°C-40°C,Relative humidity not more than 80%. | |||
Power supply:AC 100V-240V,50/60 Hz. | |||
2.A Biometer | |||
Ultrasonic frequency:10MHz | |||
Display resolution:0.01mm | |||
Total gain of receiver:90dB,user adjustable gain scope:0-32dB | |||
Measuring scope(AL):15mm-38mm | |||
Biometry accuracy:≤±0.06mm | |||
Measuring parameter:anterior chamber depth,lens thickness,vitreous length and axial length. | |||
Measuring method:automatic and manual | |||
IOL calculation:SRK/T,SRK-II,BINKHOST-II,HOLLADAY,HOFFER-Q and HAIGIS. | |||
3.Corneal Thickness Pachymeter | |||
Ultrasonic frequency:15~20MHz | |||
Display resolution:1μm | |||
Measuring scope:0.23mm-1.2mm | |||
Biometry accuracy:≤± 5μm | |||
4.Safety: | |||
Satisfy the requirements of IEC 60601-1 and IEC 60601-2-37 | |||
Features: | |||
1.Precise Measurement with both Immersion&Contact | |||
2.Extremely Easy Use | |||
3.Portable & Sleek Design | |||
4.Auto/Manual Modes | |||
5.Auto Gain Control | |||
6.Built-in thermal printer | |||
7.Clinical Accuracy: ±0.1mm | |||
8.Data with Graph Printout |