Home  >  Optical Instruments  >  Other Optics Instruments

A,AB,AP,P Scan - FPA-4

Pachymeter&A scan - more info check here: http://www.buymeasuringtools.com/A-AB-AP-P-Scan-10169586/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: A,AB,AP,P Scan Model Number: FPA-4

Product Features:

Pachymeter&A scan

Business Terms:

Port: Shanghai

Minimum Order Quantity: 1 Piece/Pieces

Payment Terms: L/C,T/T,Western Union

Contact Supplier
A,AB,AP,P Scan
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

Specification1.Working conditionsEnvironmental temperature:5°C-40°C,Relative humidity not more than 80%.Power supply:AC 100V-240V,50/60 Hz.2.Corneal Thickness PachymeterUltrasonic frequency:15~20MHzDisplay resolution:1μmMeasuring scope:0.23mm-1.2mmBiometry accuracy:≤± 5μm3.Safety:Satisfy the requirements of IEC 60601-1 and IEC 60601-2-37Features:1.Precise Measurement with both Immersion&Contact2.Extremely Easy Use3.Portable & Sleek Design4.Auto/Manual Modes5.Auto Gain Control6.Built-in thermal printer7.Clinical Accuracy: ±0.1mm8.Data with Graph PrintoutPachymeterProbe 20MHz, angle of 45 degrees makes easier operation.precision 5μmMeasure range 300μm~1500μmeach group is the average of 10 measures.Output LCD display and thermal printDisplay Large color liquid-crystal screenSINGLE mode and MAP modeA scanProbe 10MHz, with LEDDepth 15mm-35 mmPrecision ±0.05mmExamining Method immersion and contactEye Mode Phakic/ Aphakic/PseudoIOL Formula SRK-II, SRK-T, HOFFER-Q, HOLLADAY,BINKHORST-II, HAIGISCurve Freeze control by foot switch auto freeze and manual freeze.Output A scan table,thermal printer and calculationStore 10 cases(eyes), 5 reading each caseDisplay Large LCDManual and auto modes
Specification
1.Working conditions
Environmental temperature:5°C-40°C,Relative humidity not more than 80%.
Power supply:AC 100V-240V,50/60 Hz.
2.A Biometer
Ultrasonic frequency:10MHz
Display resolution:0.01mm
Total gain of receiver:90dB,user adjustable gain scope:0-32dB
Measuring scope(AL):15mm-38mm
Biometry accuracy:≤±0.06mm
Measuring parameter:anterior chamber depth,lens thickness,vitreous length and axial length.
Measuring method:automatic and manual
IOL calculation:SRK/T,SRK-II,BINKHOST-II,HOLLADAY,HOFFER-Q and HAIGIS.
3.Corneal Thickness Pachymeter
Ultrasonic frequency:15~20MHz
Display resolution:1μm
Measuring scope:0.23mm-1.2mm
Biometry accuracy:≤± 5μm
4.Safety:
Satisfy the requirements of IEC 60601-1 and IEC 60601-2-37
Features:
1.Precise Measurement with both Immersion&Contact
2.Extremely Easy Use
3.Portable & Sleek Design
4.Auto/Manual Modes
5.Auto Gain Control
6.Built-in thermal printer
7.Clinical Accuracy: ±0.1mm
8.Data with Graph Printout