corrosion test salt spray testing chamber
1. CNC, ASTM, JIS,ISO standard;
2.accuracy +/-.0.5
3.PH 6.5~7.2 3.0~3.2
4.3 years
Port: Yantian
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 500 Set/Sets per Month
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: By standard export wooden case.
Delivery Detail: Within 20 days when received 30% down payment .
90 corrosion test salt spray testing chamber
Equipment summary
Salt spray tester used to test the corrosive resistance of products whose the surface was treated with paint, lectroplating,inorganic and organic film, anode handling, anti-rust oil ...
Corresponding standard:
1.GB/T 2423.17-1993 salt spray test;
2.GB/T 2423.18-2000 salt spray test;
3.GB/T 10125-1997 salt spray test;
4.ASTM.B117-97 salt spray test;
5.JIS H8502 salt spray test;
6.IEC68-2-11 salt spray test;
7.IEC68-2-52 1996 salt spray test;
8.GB.10587-89 salt spray test;
9.CNS.4158 salt spray test;
10.CNS.4159 CASS Accelerated acetic acid copper salt spray test;
11..GB/T 12967.3-91 CASS Accelerated acetic acid copper salt spray test;
Technical parameters:
Model | HZ-2001C | HZ-2001B | HZ-2001A |
Internal dimension (cm) | 60*45*40 | 90*60*50 | 120*80*50 |
Outside box size (cm) | 107*60*118 | 141*88*128 | 190*110*140 |
Testing room temperature | Salt test (NSS ACSS) 35±1 degree / Corrosion Test (CASS)50±1 degree | ||
Pressure barrel temperature | Salt test (NSS ACSS) 47±1 degree / Corrosion Test (CASS)63±1degree | ||
Brine temperature | 35±1 50±1 | ||
Testing room Capacity | 108 L | 270 L | 480 L |
Brine tank capacity | 15 L | 25 L | 40 L |
Salt concentration | The /of copper chloride (CuCl2 2H2O) | ||
Air pressure | 1.00 ± 0.01kgf/cm2 | ||
Spray volume | 1.0~2.0ml /80cm2 /h(working at least 16 hours, and then take the average) | ||
Testing room relative humidity | 85% or above | ||
PH | 6.5~7.2 3.0~3.2 | ||
Spray form | Programmable spray (Including continuous and intermittent spray) | ||
Power | AC220V1 Φ10A | AC220V1 Φ15A | AC220V1Φ20A |