Thermocouple Calibrator -YH7021
Fluke-714 Thermo Calibrator
1)Measure temperature from TC output
2)Simulate TC output
Port: Shenzhen Port
Minimum Order Quantity: 5 Piece/Pieces
Supply Ability: 5000 Piece/Pieces per Month More can be provided according to customers' need
Payment Terms: T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: gift box for unit ,carton box for outer
Delivery Detail: Be available to customers' requirement
• Measure temperature from TC output
• Simulate TC output
• Operable with eight types of thermocouples
• Calibrate linear TC transmitter with mV source function
• Selectable °F or °C
Measure / simulate thermocouple | Range | -200 to 1800°C, depending on type |
Resolution | 0.1°C | |
Accuracy | ±(0.3°C + 10µV) * | |
Meas ure / simulate mV | Range | -10 to75mV |
Resolution | 0.01mV | |
Accuracy | ±0.02% |
*Note: 8 TC types; J K T E N R S B per NIST 175 and ITS-90Mechanical & General
Thermocouple Properties
Thermocouple Type | Temperature Ranges | Display Resolution |
J | -200~1200°C / -328~2192°F | 0.1°Cor°F |
K | -200~1370°C / -328~2498°F | 0.1°Cor°F |
T | -200~400°C / -328~752°F | 0.1°Cor°F |
E | -200~950°C / -328~1742°F | 0.1°Cor°F |
R | -20~1750°C / -4~3182°F | 1°Cor°F |
S | -20~1750°C / -4~3182°F | 1°Cor°F |
B | 600~1800°C / 1112~3272°F | 1°Cor°F |
N | -250~1300°C / -418~2372°F | 0.1°Cor°F |
Specifications are based on a one year calibration cycle and apply for ambient temperature from +18°C to +28°C unless stated otherwise. “Counts” means number of increments or decrements of the least significant digit.
Temperature Measure and Thermocouple Simulate(Maximum input voltage 30V)
Thermocouple Type | Resolution | Error | Reference Junction Error |
J, K, T, E, N | 0.1°C or °F | ±(0.3°C+10μV) | ±0.2°C |
R, S, B | 1°C or °F | ±(0.3°C+10μV) | ±0.2°C |
Maximum input voltage 30 V
Millivolt Measure and Source(Maximum input voltage 30V)
Range | Resolution | Accuracy |
-10mV~75mV | 0.01mV | ±(0.02%+2Dgt) |
Maximum input voltage:30 V
General Specifications
Maximum voltage applied between any terminal and earth ground or between any two terminals 30V
Storage temperature -40°C to 60°C
Operation temperature-10°C to 55°C
Operation altitude 3000 meters maximum
Temperature coefficient 0.05×specified accuracy per°C for temperature ranges -10°C to 18°C and 28°C to 55°C
Relative humidity 95% up to 30°C,75% up to 40°C,45% up to 50°C,and 35% up to 55°C
Vibration Random 2 g,5 Hz to 500 Hz
Shock 1 meter drop test
Power requirements: Single 9 V battery (ANSI/NEDA 1604A or IEC 6LR61)
Size 190mm L×89mm W×42mm H
Weight Approx. 350g