Home  >  Temperature Instruments

4-20ma pt100 temperature transmitter Input: RTD, TC, Ohm, mV - TMT199

pt100 temperature transmitter, Input: RTD, TC, Ohm, mV, Galvanic isolation(In/Out):2KVAC, Cold junction: Internal, Output:4-20mA - more info check here: http://www.buymeasuringtools.com/4-20ma-pt100-temperature-transmitter-Input-RTD-TC-Ohm-mV-10233188/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: SENSE Model Number: TMT199 Usage: Industrial Theory: Temperature Transmitter model: TMT199 Input: RTD/TC/Ohm/mV output: 4-20mA Isolation: 2KV Communication: HART protocol Others: LCD backlight display colour: blue

Product Features:

pt100 temperature transmitter

Input: RTD, TC, Ohm, mV

Galvanic isolation(In/Out):2KVAC

Cold junction: Internal

Output:4-20mA

Business Terms:

Port: Shanghai

Minimum Order Quantity: 1 Piece/Pieces

Supply Ability: 10000 Unit/Units per Quarter

Payment Terms: T/T

Contact Supplier
4-20ma pt100 temperature transmitter Input: RTD, TC, Ohm, mV
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: standard package

Delivery Detail: within 2 weeks after payment received

Specifications and Product Details:

4-20ma pt100 temperature transmitter TMT199
Universal Temperature Transmitter with HART-protocol for converting various input signals into a scalable 4 to 20mA analogue output signal.

Performance
*Universally progammable with HART-protocol for various input signals
*Two-wire technology, analogue output 4 to 20mA
*Highly accurate in entire operating temperature range
*Wide voltage supply range
*Customer specific measurement range settings
*Simple and user friendly software
*Multiparametric backlight rotatable LCD display

Areas of application
*Temperature Field Transmitter with HART-protocol convert various input signals into a scalable 4 to 20mA analogue output signal
*Input
Resistance thermometers(RTD)
Thermocouples(TC)
Resistance transmitters(ohm)
Voltage transmitters(mV)

Technical data
Output: 4 to 20mA
Supply voltage: 10.5 to 45VDC (with backlight LCD)
Input: RTD, TC, Ohm, mV
Operation: HART-protocol
Galvanic isolation(In/Out):2KVAC
Cold junction: Internal
Accuracy(Pt100): <0.2K or 0.08%
Influence of ambient: Negligible
Load influence: Negligible
Power supply influence: Negligible
Resolution: 0.3uA
Operation: HART-prtocol
Weight: Approx. 0.95g(with display)