1.Measuring Range: 0-150mm/0-6in
2.Material:stainless steel (4cr13)
3.Four-way measurements
4.certificate:CE
5.Display: LCD
Port: Shanghai or Ningbo
Minimum Order Quantity: 1000 Set/Sets
Supply Ability: 100000 Set/Sets per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: plastic box and blister with papercard or according to your requirements.
Delivery Detail: 30 days after deposit receiving.
150mm/6" Electronic Digital Caliper have certificate CE (E011)
Outside Jaws: Measure External Length
Inside Jaws: Measure Internal Length
Measuring Range: 0-150mm/0-6in, 0~200mm/ 0~8 in
Resolution: 0.01mm/ 0.0005in
Accuracy: ± 0.02mm/ 0.001in (<100mm)
±0.03mm/0.001in(>100-200mm)
Repeatability: 0.01mm / 0.0005in
Max Measuring Speed: 1.5m/sec, 60in/sec
Measuring System: Linear Capacitance measuring system
Display: LCD Screen
Construction Material: Stainless Steel
Power: One alkaline lithium button cell battery 1.5v,TYPE LR44.
Capacity-180MAH
Working Temperature: 5°c-40°c/41 to 104 degree f
•APPLICATIONS
1.Operation : slider can be removed only after the locking screw (#10) is loosened.
2.Basic measuring methods :
1) loosen the locking screw
2) Press "ON " button, select sae or metric measurement by pressing "MM/INCH" button.
Pressing "MM/INCH" button after measurement will display the sae / metric conversion.
3)To reset display to zero, close external measuring jaws, then press "ZERO" button.
Falure | Cause | Measure |
Display flashes | Low battery | Replace battery |
Display does not change when slider is moved | System locked | Remove battery and replace after 30 seconds to reset system |
Accuracy less than +/-0.001mm | Dirt in the sensor | Remove slider cover and its assembly, clean with compress air 5kgs/cm2 |
No display on LCD | 1.improper battery position 2. Low battery | 1. Remove battery cover and check battery position 2. Replace battery. |